Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »


An introduction to YOUnite and Adaptors can be found on the Introduction to YOUnite page and the Managing Adaptors page.

Developing adaptors can be found on the YOUnite Adaptor Guide for Java Developers page.


Adaptor Workflow

The workflow required in getting a fully functioning adaptor are as follows

  1. Develop an adaptor in your development environment using a YOUnite Adaptor SDK (see YOUnite Adaptor Guide for Java Developers)
  2. Install the adaptor on a server (e.g. on a physical server, virtual server,  instance, container, etc.) that is connected the YOUnite message bus
  3. Connect the adaptor to the native data store or service that it is connect to YOUnite  (e.g. CRM, MIS, SIS, DB, etc)
  4. Deploy the adaptor on a server (e.g. on a physical server, virtual server,  instance, container, etc.) that is connected the YOUnite message bus
  5. POST the adaptor using the YOUnite UI or YOUnite API
  6. Configure the adaptor
  7. Start the adaptor and allow it to connect to the YOUnite DataHub
  8. Manage the adaptor
    1. PAUSE an adaptor
    2. PLAY an adaptor
      1. PLAY
      2. PLAY Read Only
    3. Delete an Adaptor
    4. Get new Credentials for an adaptor

The first step is covered in the adaptor guide and steps two through four are implementation specific. The remainder of this page covers steps five through eight. 


Deploy the Adaptor


Adaptors States

blah blah

StateDescription
PostedAdaptor is successfully POSTed. An API consumer can make this request or it can be done through the YOUnite UI.
Configured

The adaptors had a:

  • Successful connection to the YOUnite Datahub via the message bus/broker
  • Subscribed to the appropriate message broker topics
  • Its message broker queue has been created
PauseThe adaptors is running but not accepting adaptor (read/write) requests.

Play Read-Only

The adaptor is accepting read requests only.
PlayThe adaptor is accepting read and write requests.


Posting and Configuring an Adaptor 

By default only the zone data steward role has permission to create an adaptor and view its credentials.  User must have XX permission.

UI screenshots. Router doc (ADAPTOR: POST & CONFIGURATION)

Adaptor Startup Sequence

Controlling an Adaptor

Permissions needed

U Screen shots

API endpoints


Updating an Adaptor


Deleting an Adaptor